ITV2090/ITV2091
VPC Pneumatic
Min. supply vacuum pressure: | |
---|---|
Max. supply vacuum pressure: | |
Set pressure range: | |
Working temperature: | |
Availability: | |
Product Description
For the stepless control of vacuum pressure in proportion to electrical signals.
● Controls air pressure in proportion to an electric signal.
● Pressure range of -1.3 to -80kPa.
● Available port size 1/4
● Mounting bracket option
Product Specification
Model | ITVX2090 | ITVX2091 | |
Min. supply vacuum pressure*1) | Set pressure -13.3 kPa | ||
Max. supply vacuum pressure | -101kPa | ||
Set pressure range | -1.3 to -80kPa | ||
Power supply | Voltage | DC24V±10% | DC12 to 15V |
Current consumption | Power supply voltage DC24 V type: 0.12 A or less*6) Power supply voltage DC12 to 15 V type: 0.18 A or less | ||
Input signal | Current type*2) | DC4 to 20mA, DC0 to 20mA (Sink type) | |
Voltage type | DC0 to 5V, DC0 to 10V | ||
Preset input | 4 points (Negative common), 16 points (No common polarity) | ||
Input impedance | Current type | 250Ω or less*3) | |
Voltage type | Approx. 6.5 kΩ | ||
Preset input | Power supply voltage DC24 V type: Approx. 4.7 kΩ Power supply voltage DC12 V type: Approx. 2.0 kΩ | ||
Output signal*4) (Monitor output) | Analog output | DC1 to 5 V (Output impedance: Approx. 1 kΩ) DC4 to 20 mA (Sink type) (Output impedance: 250 Ω or less) Output accuracy ±6% F.S. or less | |
Switch output | NPN open collector output: Max. 30 V, 80 mA PNP open collector output: Max. 80 mA | ||
Linearity | ±1% F.S. or less | ||
Hysteresis | 0.5% F.S. or less | ||
Repeatability | ±0.5% F.S. or less | ||
Sensitivity | 0.2% F.S. or less | ||
Temperature characteristics | ±0.12% F.S./℃ or less | ||
Output pressure display | Accuracy | ±2% F.S. ±1 digit or less | |
Unit | kPa*5) Min. display: 1 | ||
Working temperature | 0 to 50℃ (No condensation) | ||
Enclosure | IP65 | ||
Weight | 350g |
*1) The min. supply vacuum pressure should be 13.3 kPa less than the max. vacuum pressure setting value.
*2) DC4 to 20 mA is not possible with the 2-wire type. Power supply voltage (DC24 V or DC12 to 15 V) is required.
*3) Value for the state with no over current circuit included. If an allowance is provided for an over current circuit, the input impedance varies depending on the input power supply. This is 350 Ω or less for an input current of DC20 mA When measuring ITV analog output from DC1 to 5 V, if the load impedance is less than 100 kΩ, the analog output monitor accuracy of within ±6% (full span) may not be available. The product with the accuracy of within ±6% is supplied upon your request. Output pressure remains unaffected.
*4) Either analog output or switch output must be selected. Furthermore, when switch output is selected, either NPN output or PNP output must also be selected. Use caution that the preset input type is not equipped with an output signal function.
*5) Please contact VPC regarding indication with other units of pressure.
*6) Refer to the table below for communication specifications.
Flow rate characteristics measurement conditions
● Exhaust flow rate of the vacuum pump used for measurement: 500 L/min (ANR)
● Inlet vacuum pressure: –100 kPa [When outlet flow rate is 0 L/min (ANR)]
● Max. flow rate: 132 L/min (ANR) (With inlet vacuum pressure at –39 kPa)
Main Dimensions
Description | Part No. | |
Flat bracket assembly (including mounting screws) | P398020-600 | |
L-bracket assembly (including mounting screws) | P398020-601 | |
Power cable connector (4 cores) | Straight type 3 m | P398020-500-3 |
Right angle type 3 m | P398020-501-3 |
Catalogue PDF