PSE560
VPC Pneumatic
8481804090
Working medium: | |
---|---|
Set pressure range: | |
Enclosure rating: | |
Availability: | |
Product Description
1. PSE560 is for a standard pneumatic system's pressure range, while the PSE564 model is for low pressure.
2. General purpose remote pressure sensor for liquid or gas at 1 MPa or less.
3. Includes a fixed cable with field wired connector option.
4. Oil-free (single diaphragm construction), Enclosure rating IP65.
Description | Part No. | Material | Note |
Connector for pressure sensor controller | ZS-28-C | — | 1pc. |
Adapter with restrictor Rc1/4 | ZS-31-X175 | stainless steel 304 | 1pc. |
Adapter with restrictor NPT1/4 | ZS-31-X186 | 1pc. | |
Adapter with restrictor Rc1/8 | ZS-31-X188 | 1pc. | |
Adapter with restrictor NPT1/8 | ZS-31-X189 | 1pc. | |
Orifice M5 | ZS-48-A | stainless steel 303 | 1pc. |
Product Specification
Model | PSE560 (Positive pressure) | PSE561 (Vacuum pressure) | PSE563 (Compound pressure) | PSE564 (Positive pressure) | |
Rated pressure range | 0 to 1MPa | 0 to -101kPa | -100 to -100kPa | 0 to 500kPa | |
Extension analog output range | -0.1 to 0MPa | 10.1 to 0kPa | — | -50 to 0kPa | |
Proof pressure | 1.5MPa | 500kPa | 500kPa | 750kPa |
Model | PSE56□-□ | PSE56□-□-28 | |
Working medium | Liquid or gas that will not corrode or attack stainless steel 316L | ||
Power supply voltage | DC12 to 24 V±10%, Ripple (p-p) 10% or less (with reverse connection protection) | ||
Current consumption | 10mA or less | — | |
Output specifications | Analog output: 1 to 5V (within rated pressure range) 0.6 to 1V (within extension analog output range) Output impedance: Approx.1kΩ | Analog output: DC4 to 20 mA (within rated pressure range) Maximum load impedance: 500Ω or less (at DC24 V) 100Ω or less (at DC12 V) | |
Accuracy (Ambient temperature at 25℃) | ±1%F.S. (within rated pressure range ), ±3%F.S. (within extension analog output range) | ||
Linearity | ±0.5% F.S. | ||
Repeatability | ±0.2% F.S. | ||
Power supply voltage effect | ±0.3% F.S. | ||
Environment | Enclosure | IP65 | |
Operating temperature | Operating: 10 to 60℃, Stored: -20 to 70℃ (No freezing or condensation) | ||
Operating humidity | Operating/Stored: 35 to 85% RH (No condensation) | ||
Withstand voltage | AC250V for 1 minute between terminals and housing | ||
Insulation resistance | 50MΩ or more (DC 50V measured via megohmmeter) between terminals and housing | ||
Temperature characteristics | ±2% F.S. (0 to 50°C: 25°C reference), ±3% F.S. (–10 to 60°C: 25°C reference)
| ||
Sensor cable | PSE56 - : Oilproof heavy-duty vinyl cable with air tubing, 3 cores, Φ5.1, 3 m, Conductor area: 0.2 mm², Insulator O.D.: 1.12 mm PSE56 - -28: Oilproof heavy-duty vinyl cable with air tubing, 2 cores, Φ5.1, 3 m, Conductor area: 0.2 mm², Insulator O.D.: 1.12 mm | ||
Piping material | Case: C3604 + Nickel plating, Piping port/Pressure sensor: Stainless steel 316L, Grease-free | ||
Standards | CE marking (EMC directive/RoHS directive), UL/CSA (E216656) |
Range | Rated pressure range | A | B | C |
For vacuum pressure | 0 to -101kPa | 0kPa | -101kPa | 10.1kPa |
For compound pressure | -100 to 100kPa | -100kPa | 100kPa | ― |
For positive pressure | 0 to 1MPa | 0kPa | 1MPa | -0.1MPa |
0 to 500kPa | 0kPa | 500kPa | -50kPa |
Main Dimensions
* The dimensions of part C are common to all PSE56 models.
* Be sure to release the air in the air tubing of the cable to the atmosphere. If the air tubing is restricted, or left in environments where it is exposed to water or oil, it cannot be detected normally