VUS
VPC Pneumatic
8481804090
Working medium: | |
---|---|
Availability: | |
Product Specification
VUS - 32① - N② V③ - 01④
① VUS - 32 → Pressure range
Code | Pressure range |
VUS - 32R | Compound (-101.0~101.0 kPa) |
VUS - 32 | Vacuum (10.0~-101.3 kPa) |
SUS - 32 | Positive (-0.100~1.000 MPa) |
② N → Output Specifications
Code | Output Specifications |
N | NPN Output |
P | PNP Output |
③ V → Output Specifications
Code | Output Specifications |
V | 2 Output + 1 Analog output(1-5V) |
2 | 2 Output + Copy Function |
.
④ 01 → Port
Code | Port |
01 | R1/8,M5 |
N1U | NPT1/8, #10-32 UNF |
G1 | G1/8,M5 |
Product Description
Type | SUS-32 (Positive) | VUS-32 (Vacuum) | VUS-32R (Compound) | |
Rated pressure range | 0 to1.0MPa | 0 to -101.3kPa | -100.0 to 100.0kPa | |
Setting pressure range | -0.1 to 1.0MPa | 10.0 to -101.3kPa | -101.0 to 101.0kPa | |
Withstand pressure | 1.5MPa | 300kPa | ||
Fluid | Filtered air, Non-corrosive / Non-flammable gas | |||
Set pressure resolution (*2) | kPa | – | 0.1 | |
MPa | 0.001 | – | ||
kgf/cm2 | 0.01 | 0.001 | ||
bar | 0.01 | 0.001 | ||
psi | 0.1 | 0.01 | ||
inHg | – | 0.1 | ||
mmHg | – | 1 | ||
Power supply voltage | 12 to 24V DC ±10%, Ripple (P-P) 10% or less | |||
Current consumption | ≦ 40mA (With no load) | |||
Switch output | NPN: open collector 2 outputs PNP: open collector 2 outputs Max. load current: 125mA Max. load current: 125mA Max. supply voltage: 30V DC Max. supply voltage: 24V DC Residual voltage: ≦ 1.5V Residual voltage: ≦ 1.5V | |||
Repeatability(Switch output) | ±0.2% F.S. ±1 digit | |||
Hysteresis | One point set mode | Adjustable (*1) | ||
Hysteresis mode | ||||
Window comparator mode | ||||
Response time | ≦ 2.5ms (chattering-proof function: 25ms, 100ms, 250ms, 500ms, 1000ms and 1500ms selections) | |||
Output short circuit protection | Yes | |||
7 segment LCD display | Two color(Red/Green) main & unit display, Orange sub-display (Sampling rate: 5 times/1sec.) | |||
Indicator accuracy | ±2% F.S. ±1 digit (ambient temperature: 25 ±3°C) | |||
Switch ON Indicator | Orange (1 & 2 Indicator) OUT1 OUT2 | |||
Analog output (Voltage Output) | Output Voltage: 1 to 5V ±2.5% F.S. (within rated pressure range) Linearity: ±1% F.S. Output impedance: about 1kΩ | |||
Environment | Enclosure | IP40 | ||
Ambient temp. range | Operation: 0 ~ 50°C, Storage:-10 ~ 60°C (No condensation or freezing) | |||
Ambient humidity range | Operation/Storage: 35 ~ 85% RH (No condensation) | |||
Withstand voltage | 1000V AC in 1-min (between case and lead wire) | |||
Insulation resistance | 50M (at 500V DC, between case and lead wire) | |||
Vibration | Total amplitude 1.5mm or 10G,10Hz-55Hz-10Hz scan for 1 minute, two hours each direction of X, Y and Z | |||
Shock | 100m/s (10G), 3 times each in direction of X, Y and Z | |||
Temperature characteristic | ±2.5% F.S. of detected pressure (25°C) at temp. Range of 0~50°C | |||
Port size | 01:R1/8", M5; N1U:NPT1/8", #10-32UNF; G1: G1/8", M5 | |||
Lead wire | Oil-resistance cable(0.15mm2 ) |
*1.Hysteresis value is adjustable within 1 ~ 8 digits for one point set mode and window comparator mode.
*2.Pressure unit switching feature is disabled at the factory.
Setting steps for the function active.
1) Turn on pressing “set” and “down” key.
2) Press “down” key → display “on”.
3) Press “set” key.