PF2A Series Digital Flow Switch For Air, Integrated type

Share to:
1. The PF2A is suitable for applications requiring a metered quantity of air, such as for supply confirmation, filling accumulation, or fixed supply consumption.
2. The display can be rotated in 90 degree increments, offering better operation visibility.
3. The thermal sensor is protected in a bypass flow path to reduce contact with moisture and contaminants, avoiding accuracy deterioration and damage.
4. The PF2A has an IP65 ingress protection rating and is both RoHS and CE compliant.
  • PF2A710

  • VPC Pneumatic

  • 8481804090

Working medium:
Working temperature:
Proof pressure:
Accuracy:
Accumulated flow range:
Availability:

Product Specification

 Product Feature

1. Flow rate setting and monitoring are possible with the digital display.

2. Integrated type and separate monitor types are available.

3. Three types of output: Switch, accumulated pulse, and analog outputs.

4. Capable of switching back and forth between cumulative and instantaneous flow.

5. 4-channel Flow Monitor: 4 independent flow rate ranges can be monitored by a single controller.


pf2a

Product Description

Model
PF2A710 PF2A750 PF2A711 PF2A721 PF2A751
Working medium Dry Air, Nitrogen
Rated flow range 1 to 10L/min 5 to 50L/min 10 to 100L/min 20 to 200L/min 50 to 500L/min
Mininum set unit 0.1L/min 0.5L/min 1L/min 2L/min 5L/min
Accumulated pulse flow rate exchange value(Pluse width:50ms) 0.1L/pulse 0.5L/pulse 1L/pulse 2L/pulse 5L/pulse
Display units*1,2)
Instantaneous flow rate L/min, CFM×10 -2 L/min, CFM×10 -1
Accumulated flow L, ft³×10 -1
Working temperature 0 to 50℃
Accuracy*3) ±5%F.S.
Repeatability ±1%F.S. ±2%F.S.
Temperature characteristics ±3%F.S. (15 to 35℃, 25℃ reference), ±5%F.S. (0 to 50℃, 25℃ reference)
Current consumption 150mA or less 160mA or less 170mA or less
Port size(Rc, NPT, G) 1/8, 1/4 3/8 1/2
Detection type Heater type
Operating pressure -50kPa to 0.5MPa -50kPa to 0.75MPa
Proof pressure 1.0MPa
Accumulated flow range*4)
0 to 999999L
Output specifications*5) Switch output NPN open collector Max. load current: 80mA; Internal voltage drop: 1V or less 

Max. applied voltage: 30V; 2outputs

PNP open collector Max. load current: 80mA;

Internal voltage drop: 1.5V or less; 2outputs

Accumulated pulse output NPN or PNP open collector (same as switch output)
Status LED's Lights up when output is turned ON OUT1: Green; OUT2: Red
Response time 1 sec. or less
Hysteresis Hysteresis mode: Variable (can be set from 0), Window comparator mode : 3-digit fixed
Power supply voltage DC12 to 24 V±10%
Environment Enclosure IP65
Working temperature Operating: 0 to 50℃, Stored: -25 to 85℃ (with no freezing and condensation)
Withstand voltage AC 1000V for 1 minute between terminals and housing
Insulation resistance 50MΩ or more (DC 500V measured via megohmmeter) between terminals and housing
Noise resistance 1000V P-P pulse width1μs lasts 1ns

*1) For digital flow switch with unit switching function. (Fixed SI unit [(L/min, or L, m³ or m³×10³)] will be set for switch type without the unit switching function.) 

*2) Flow rate display can be switched between the basic condition of 0℃, 101.3 kPa and the standard condition (ANR) of 20℃, 101.3 kPa, and 65% RH. 

*3) The piping on the IN side must have a straight section of piping whose length is 8 times the piping diameter or more. If a straight section of piping is not installed, the accuracy may vary by±5% F.S. or more. 

*4) Accumulated flow rate is reset when the power supply turns OFF. 

*5) Switch output and accumulated pulse output can be selected during initial setting. 

*6) Window comparator mode — Since hysteresis will reach 3 digits, keep P_1 and P_2 or n_1 and n_2 apart by 7 digits or more. (In case of output OUT2, n_1, 2 to be n_3, 4 and P_1, 2 to be P_3, 4.) 

*7) For details about wiring and thread type, please contact VPC. 

*8) Any products with tiny scratches, smears, or display color variation or brightness which does not affect the performance are verified as conforming products.


■ Analogue Output

Part No. Min. rated flow rate value Max. rated flow rate value
PF2A710 1NL/min 10NL/min
3.5CFM×10-2 35.0CFM×10-2
PF2A750 5NL/min 50NL/min
18.0CFM×10-2 176.0CFM×10-2
PF2A711 10NL/min 100NL/min
3.5CFM×10-1 35.5CFM×10-1
PF2A721 20NL/min 200NL/min
7.0CFM×10-1 71.0CFM×10-1
PF2A751 50NL/min 500NL/min
18.0CFM×10-1 176.0CFM×10-1

* When using the analog output of the standard state, please convert according to the following formula.  

   Base state flow rate value ÷ 0.927 = Standard state flow rate value.


flow meter digital output

Main Dimensions

■ Analogue Output

digital flow sensor


smc flow switchdigital air flow sensor