PF2A703H
VPC Pneumatic
8481804090
Working medium: | |
---|---|
Working temperature: | |
Proof pressure: | |
Accuracy: | |
Accumulated flow range: | |
Rated flow range: | |
Availability: | |
Product Specification
1. High flow rate range: 150 to 12000L/min(ANR).
2. Flow rate can be set and detected.
3. Three types of output: real-time switch output, accumulated switch output, or accumulated pulse output can be selected as an output type.
4. Digital displays of instantaneous flow rate and accumulated flow rate can be selected.
5. 4-channel Flow Monitor: 4 independent flow rate ranges can be monitored by a single controller.
Product Description
Model | PF2A703H | PF2A706H | PF2A712H | |
Working medium | Dry Air, Nitrogen | |||
Detection type | Heater type | |||
Rated flow range*1) | 150 to 3000L/min | 300 to 6000L/min | 600 to 12000L/min | |
Mininum set unit*1) | 5L/min | 10L/min | ||
Display units*2) | Instantaneous flow rate | L/min, CFM | ||
Accumulated flow | L, m³, m³×10³, ft³, ft³×10³, ft³×106 | |||
Operating pressure | 0.1 to 1.5MPa | |||
Proof pressure | 2.25MPa | |||
Pressure loss | 20kPa (at maximum flow rate) | |||
Accumulated flow range*3) | 0 to 9,999,999,999L | |||
Accuracy*5) | ±1.5%F.S. (0.7MPa, at 20℃) | |||
Repeatability | ±1.0% F.S. (0.7MPa, at 20℃ ), ±3.0% F.S. in case of analog output | |||
Pressure characteristics | ±1.5% F.S. (0.1 to 1.5 MPa, 0.7 MPa reference) | |||
Temperature characteristics | ±2.0% F.S. (0 to 50℃, 25℃ reference) | |||
Output specifications | Switch output*5) | NPN open collector | Max. load current: 80 mA; Max. applied voltage: 30 V; Internal voltage drop: 1 V or less (with load current of 80 mA) | |
PNP open collector Max. load current: 80 mA;Internal voltage drop: 1.5 V or less | ||||
Accumulated pulse output*5) | NPN or PNP open collector | Flow rate per pulse: 100 L/pulse, 10.0 ft³/pulse, ON time per pulse width: 50 msec/pulse | ||
Analog output*6) | Output voltage: 1 to 5 V; Min. load impedance: 100 kΩ (Output impedance: 1 kΩ) | |||
Output current: 4 to 20 mA; Max. load impedance: 250 Ω | ||||
Response time | 1 sec. or less | |||
Hysteresis | Hysteresis mode: Variable (can be set from 0); Window comparator mode: Fixed (can be set from 0 to 3% F.S.) | |||
Power supply voltage | DC24 V±10% | |||
Current consumption | 450mA or less | |||
Environment | Enclosure | IP65 | ||
Working temperature | 0 to 50℃ (with no freezing and condensation) | |||
Withstand voltage | AC 1000V for 1 minute between terminals and housing | |||
Insulation resistance | 50MΩ or more (DC 500V measured via megohmmeter) between terminals and housing | |||
Noise resistance | 1000V P-P pulse width1μs lasts 1ns | |||
Standards and regulations | CE, RoHS | |||
Weight | 1.1kg (without lead wire) | 1kg (without lead wire) | 2kg (without lead wire) | |
Port size (Rc, NPT, G) | 1 | 1 1/2 | 2 |
*1) Flow rate display can be switched between the basic condition of 0°C, 101.3 kPa and the standard condition (ANR) of 20°C, 101.3 kPa, and 65% RH.
*2) For digital flow switch with unit switching function. (Fixed SI unit [(L/min, or L, m³ or m³×10³)] will be set for switch type without the unit switching function.)
*3) Accumulated flow rate is reset when the power supply turns OFF. It is possible to select a function that holds the accumulated value so it is not reset. In such cases, data is written on EEPROM (electrically erasable programmable read-only memory) at approximately four-minute intervals. When using, please take into consideration that the EEPROM writing is guaranteed up to 1 million times (four minutes × 1 million = 4 million ≈ 7.9 years)
*4) The high flow rate type is CE marking compatible; however, the linearity with applied noise is ±5% F.S. or less.
*5) Switch output and accumulated pulse output selections are made using the button controls.
*6) The analog output operates only for instantaneous flow rate, and does not operate for accumulated flow.
Main Dimensions
Catalogue PDF