VT317
VPC Pneumatic
Working pressure: | |
---|---|
Working temperature: | |
Impact/Vibration resistance: | |
Type of actuation: | |
Port size: | |
Thread type: | |
Availability: | |
Product Description
VT317 3-port poppet type solenoid valve is often used in applications where precise control of fluid flow is required.
1. Compact valve body design provides high flow rates.
2. The poppet and seat design can provide a very effective seal, reducing leaks and improving efficiency.
3. Suitable for use in vacuum and pneumatic applications.
4. A single valve with 6 valve functions.
5. Selective porting can provide 6 valve functions, such as N.C. valve, N.O. valve, Divider valve, Selector valve etc.
Model | Applicable manifold type | Accessory |
VO317(-Q) | Common or individual exhaust | O-ring (4 pcs.)* Hexagon socket head screw (2 pcs.) |
* It is not applied to “Continuous duty type”. Refer to the accessories on page 5.
Product Specification
Type of actuation | Direct operated type 2 position single solenoid |
Working medium | Air |
Working pressure | 0 to 0.9 MPa |
Working temperature | –10 to 50°C (No freezing) |
Response time*1) | 30 ms or less (at the pressure 0.5 MPa) |
Max. operating frequency | 10 Hz |
Lubrication | Not required (Use turbine oil Class 1 lSO VG32, if lubricated.) |
Manual override | Push type (Non-locking) |
Mounting orientation | Unrestricted |
Impact/Vibration resistance*2) | 150/50 m/s² |
Enclosure | Dustproof |
Electrical entry | Grommet, Conduit, Conduit terminal, DIN terminal | ||
Coil rated voltage | AC (50/60 Hz) | 100V, 200V, 110V*, 220V*, 240V* | |
DC | 24V, 12V* | ||
Allowable voltage fluctuation | -15 to +10% of rated voltage | ||
Apparent power*3) | AC | Inrush | 19 VA (50 Hz), 16 VA (60 Hz) |
Holding | 11 VA (50 Hz), 7 VA (60 Hz) | ||
Power consumption*3) | DC | Without indicator light: 6 W, With indicator light: 6.3 W | |
Light/Surge voltage suppressor (Not applicable for grommet type) | AC | Varistor, Neon bulb | |
DC | Varistor, LED(Neon bulb for 100V or more) |
* Semi-standard.
*1) Based on dynamic performance test, JIS B 8419: 2010. (Coil temperature: 20°C, at rated voltage, without surge voltage suppressor)
*2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 1000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period)
*3) At rated voltage.
Valve model | 1→2(P→A) | 2→3(A→R) | 3→2(R→A) | 2→1(A→P) | ||||||||
C [dm³/(s·bar)] | b | Cv | C [dm³/(s·bar)] | b | Cv | C [dm³/(s·bar)] | b | Cv | C [dm³/(s·bar)] | b | Cv | |
VT317 | 2.4 | 0.26 | 0.62 | 2.6 | 0.34 | 0.67 | 2.8 | 0.25 | 0.67 | 2.5 | 0.37 | 0.66 |
VT317V (Vacuum spec. type) | ||||||||||||
VT317E (Continuous duty type) |
* Values for a single valve unit. It differs in the manifold case. Refer to manifold specifications on page 5.
Continuous duty type: VT317E
Exclusive use of VT317E is recommended for continuous duty with long time loading.
▲ Caution
1. This model is for continuous duty, not for high cycle rates. But even in low cycle rates, if energizing the valve more than once a day, please consult with VPC.
2. Energizing solenoid should be done at least once in 30 days.
Vacuum spec. type: VT317V
This vacuum model has less air leakage than the standard model under low pressure. It is recommended for vacuum application.
▲ Caution
1. Since this valve has slight air leakage, it can not be used for vacuum holding (including positive pressure holding) in the pressure container.
Specifications different from standard are as follows.
Operating pressure range | -101.2 kPa to 0.1 MPa |
Main Dimensions